{"id":2060,"date":"2026-07-28T12:22:59","date_gmt":"2026-07-28T12:22:59","guid":{"rendered":"https:\/\/wicom.com\/gasgenerator\/?page_id=2060"},"modified":"2026-08-19T22:02:54","modified_gmt":"2026-08-19T22:02:54","slug":"g6-stickstoff","status":"publish","type":"page","link":"https:\/\/wicom.com\/gasgenerator\/stickstoffgenerator\/g6-stickstoff\/","title":{"rendered":"G6 Stickstoff"},"content":{"rendered":"<section class=\"bde-section-2060-101 bde-section\">\n              \n  \n  \n\t\n\n  <div class=\"section-background-overlay\"><\/div>\n\n\n<div class=\"section-container\"><div class=\"bde-div-2060-102 bde-div\">\n  \n  \n\t\n\n\n\n<div class=\"bde-div-2060-103 bde-div\">\n  \n  \n\t\n\n\n\n<div class=\"bde-div-2060-104 bde-div\">\n  \n  \n\t\n\n\n\n<div class=\"bde-text-2060-105 bde-text\">\nHochreiner Stickstoff und Trockenluft f\u00fcr Analyseger\u00e4te\n<\/div><h1 class=\"bde-heading-2060-106 bde-heading\">\nG6\/G7 \u2013 Stickstoff- und Trockenluftgeneratoren\n<\/h1><div class=\"bde-text-2060-656 bde-text\">\nDie Parker G6\/G7-Generatoren erzeugen hochreinen Stickstoff und trockene Druckluft f\u00fcr analytische Anwendungen. Sie eignen sich insbesondere f\u00fcr Analyseger\u00e4te, die eine kontinuierliche und zuverl\u00e4ssige Versorgung mit beiden Gasen ben\u00f6tigen. Je nach Modell stehen unterschiedliche Durchflussleistungen f\u00fcr Stickstoff und Trockenluft zur Verf\u00fcgung.<br><br>Der G6010 liefert bis zu 0,6 l\/min Stickstoff und 1,5 l\/min Trockenluft, w\u00e4hrend der G7010 bis zu 3 l\/min Stickstoff und 3 l\/min Trockenluft bereitstellt. Beide Modelle erzeugen Stickstoff mit einer Reinheit von > 99,999 % bei einem Ausgangsdruck von bis zu 5 bar.<br><br>Die Generatoren arbeiten als kompakte Plug-and-Play-Systeme mit integriertem \u00f6lfreiem Kompressor. Dadurch erm\u00f6glichen sie eine bedarfsgerechte Gasversorgung direkt im Labor, ohne separate Stickstoffflaschen oder eine zus\u00e4tzliche Druckluftquelle. Die zuverl\u00e4ssige Technik und der geringe Bedien- und Wartungsaufwand unterst\u00fctzen stabile und reproduzierbare Analysebedingungen.\n<\/div>\n<\/div><div class=\"bde-div-2060-110 bde-div\">\n  \n  \n\t\n\n\n\n<img decoding=\"async\" class=\"bde-image2-2060-111 bde-image2\" src=\"https:\/\/wicom.com\/gasgenerator\/wp-content\/uploads\/2026\/07\/G6-0-1-0-E_Front-Right.webp\" loading=\"lazy\" srcset=\"https:\/\/wicom.com\/gasgenerator\/wp-content\/uploads\/2026\/07\/G6-0-1-0-E_Front-Right.webp 1865w, https:\/\/wicom.com\/gasgenerator\/wp-content\/uploads\/2026\/07\/G6-0-1-0-E_Front-Right-243x300.webp 243w, https:\/\/wicom.com\/gasgenerator\/wp-content\/uploads\/2026\/07\/G6-0-1-0-E_Front-Right-828x1024.webp 828w, https:\/\/wicom.com\/gasgenerator\/wp-content\/uploads\/2026\/07\/G6-0-1-0-E_Front-Right-768x950.webp 768w, https:\/\/wicom.com\/gasgenerator\/wp-content\/uploads\/2026\/07\/G6-0-1-0-E_Front-Right-1242x1536.webp 1242w, https:\/\/wicom.com\/gasgenerator\/wp-content\/uploads\/2026\/07\/G6-0-1-0-E_Front-Right-1656x2048.webp 1656w\" sizes=\"(max-width: 1865px) 100vw, 1865px\"><div class=\"bde-div-2060-515 bde-div\">\n              \n  \n  \n\t\n\n\n\n<div class=\"bde-text-2060-768 bde-text\">\n> 99,9995 %\n<\/div><div class=\"bde-text-2060-517 bde-text\">\nStickstoffreinheit\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div><\/div>\n<\/section><section class=\"bde-section-2060-112 bde-section\">\n  \n  \n\t\n\n\n\n<div class=\"section-container\"><div class=\"bde-div-2060-113 bde-div\">\n  \n  \n\t\n\n\n\n<div class=\"bde-div-2060-114 bde-div\">\n  \n  \n\t\n\n\n\n<div class=\"bde-text-2060-115 bde-text\">\n> 99,999 % Stickstoffreinheit\n<\/div>\n<\/div><div class=\"bde-div-2060-116 bde-div\">\n  \n  \n\t\n\n\n\n<div class=\"bde-text-2060-117 bde-text\">\nBis zu 3 l\/min Stickstoff\n<\/div>\n<\/div><div class=\"bde-div-2060-118 bde-div\">\n  \n  \n\t\n\n\n\n<div class=\"bde-text-2060-119 bde-text\">\nBis zu 3 l\/min Trockenluft\n<\/div>\n<\/div><div class=\"bde-div-2060-120 bde-div\">\n  \n  \n\t\n\n\n\n<div class=\"bde-text-2060-121 bde-text\">\nBis zu 5 bar Ausgangsdruck\n<\/div>\n<\/div><div class=\"bde-div-2060-122 bde-div\">\n  \n  \n\t\n\n\n\n<div class=\"bde-text-2060-123 bde-text\">\nIntegrierter \u00f6lfreier Kompressor\n<\/div>\n<\/div>\n<\/div><\/div>\n<\/section><section class=\"bde-section-2060-126 bde-section\">\n              \n  \n  \n\t\n\n\n\n<div class=\"section-container\"><div class=\"bde-div-2060-127 bde-div\">\n  \n  \n\t\n\n\n\n<div class=\"bde-div-2060-128 bde-div\">\n  \n  \n\t\n\n\n\n<div class=\"bde-div-2060-129 bde-div\">\n  \n  \n\t\n\n\n\n<img decoding=\"async\" class=\"bde-image2-2060-130 bde-image2\" src=\"https:\/\/wicom.com\/gasgenerator\/wp-content\/uploads\/2026\/06\/Wasserstoffgeneratoren-Produkteigenschaften.webp\" alt=\"Wasserstoffgeneratoren Produkteigenschaften\" loading=\"lazy\" srcset=\"https:\/\/wicom.com\/gasgenerator\/wp-content\/uploads\/2026\/06\/Wasserstoffgeneratoren-Produkteigenschaften.webp 1000w, https:\/\/wicom.com\/gasgenerator\/wp-content\/uploads\/2026\/06\/Wasserstoffgeneratoren-Produkteigenschaften-300x196.webp 300w, https:\/\/wicom.com\/gasgenerator\/wp-content\/uploads\/2026\/06\/Wasserstoffgeneratoren-Produkteigenschaften-768x502.webp 768w, https:\/\/wicom.com\/gasgenerator\/wp-content\/uploads\/2026\/06\/Wasserstoffgeneratoren-Produkteigenschaften-600x392.webp 600w\" sizes=\"(max-width: 1000px) 100vw, 1000px\">\n<\/div><div class=\"bde-div-2060-134 bde-div\">\n  \n  \n\t\n\n\n\n<div class=\"bde-text-2060-135 bde-text\">\nProduktmerkmale\n<\/div><div class=\"bde-icon-list-2060-144 bde-icon-list\">\n<ul>\n  \n              \n    <li>\n              <div class='bde-icon-list__item-wrapper'>\n      \n      <span class='bde-icon-list__icon' aria-hidden='true'>\n        <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 512 512\"><!--! Font Awesome Free 6.5.1 by @fontawesome - https:\/\/fontawesome.com License - https:\/\/fontawesome.com\/license\/free (Icons: CC BY 4.0, Fonts: SIL OFL 1.1, Code: MIT License) Copyright 2023 Fonticons, Inc. --><path d=\"M256 512A256 256 0 1 0 256 0a256 256 0 1 0 0 512z\"\/><\/svg>\n      <\/span>\n      <span class='bde-icon-list__text' >\n      Hochreiner Stickstoff mit einer Reinheit von > 99,999 %\n      <\/span>\n              <\/div>\n      \n    <\/li>\n\n  \n              \n    <li>\n              <div class='bde-icon-list__item-wrapper'>\n      \n      <span class='bde-icon-list__icon' aria-hidden='true'>\n        <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 512 512\"><!--! Font Awesome Free 6.5.1 by @fontawesome - https:\/\/fontawesome.com License - https:\/\/fontawesome.com\/license\/free (Icons: CC BY 4.0, Fonts: SIL OFL 1.1, Code: MIT License) Copyright 2023 Fonticons, Inc. --><path d=\"M256 512A256 256 0 1 0 256 0a256 256 0 1 0 0 512z\"\/><\/svg>\n      <\/span>\n      <span class='bde-icon-list__text' >\n      Gleichzeitige Versorgung mit hochreinem Stickstoff und trockener Druckluft\n      <\/span>\n              <\/div>\n      \n    <\/li>\n\n  \n              \n    <li>\n              <div class='bde-icon-list__item-wrapper'>\n      \n      <span class='bde-icon-list__icon' aria-hidden='true'>\n        <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 512 512\"><!--! Font Awesome Free 6.5.1 by @fontawesome - https:\/\/fontawesome.com License - https:\/\/fontawesome.com\/license\/free (Icons: CC BY 4.0, Fonts: SIL OFL 1.1, Code: MIT License) Copyright 2023 Fonticons, Inc. --><path d=\"M256 512A256 256 0 1 0 256 0a256 256 0 1 0 0 512z\"\/><\/svg>\n      <\/span>\n      <span class='bde-icon-list__text' >\n      Je nach Modell bis zu 3 l\/min Stickstoff und 3 l\/min Trockenluft\n      <\/span>\n              <\/div>\n      \n    <\/li>\n\n  \n              \n    <li>\n              <div class='bde-icon-list__item-wrapper'>\n      \n      <span class='bde-icon-list__icon' aria-hidden='true'>\n        <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 512 512\"><!--! Font Awesome Free 6.5.1 by @fontawesome - https:\/\/fontawesome.com License - https:\/\/fontawesome.com\/license\/free (Icons: CC BY 4.0, Fonts: SIL OFL 1.1, Code: MIT License) Copyright 2023 Fonticons, Inc. --><path d=\"M256 512A256 256 0 1 0 256 0a256 256 0 1 0 0 512z\"\/><\/svg>\n      <\/span>\n      <span class='bde-icon-list__text' >\n      Ausgangsdruck von bis zu 5 bar\n      <\/span>\n              <\/div>\n      \n    <\/li>\n\n  \n              \n    <li>\n              <div class='bde-icon-list__item-wrapper'>\n      \n      <span class='bde-icon-list__icon' aria-hidden='true'>\n        <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 512 512\"><!--! Font Awesome Free 6.5.1 by @fontawesome - https:\/\/fontawesome.com License - https:\/\/fontawesome.com\/license\/free (Icons: CC BY 4.0, Fonts: SIL OFL 1.1, Code: MIT License) Copyright 2023 Fonticons, Inc. --><path d=\"M256 512A256 256 0 1 0 256 0a256 256 0 1 0 0 512z\"\/><\/svg>\n      <\/span>\n      <span class='bde-icon-list__text' >\n      Geeignet f\u00fcr Analyseger\u00e4te mit Bedarf an Stickstoff und Trockenluft\n      <\/span>\n              <\/div>\n      \n    <\/li>\n\n  \n              \n    <li>\n              <div class='bde-icon-list__item-wrapper'>\n      \n      <span class='bde-icon-list__icon' aria-hidden='true'>\n        <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 512 512\"><!--! Font Awesome Free 6.5.1 by @fontawesome - https:\/\/fontawesome.com License - https:\/\/fontawesome.com\/license\/free (Icons: CC BY 4.0, Fonts: SIL OFL 1.1, Code: MIT License) Copyright 2023 Fonticons, Inc. --><path d=\"M256 512A256 256 0 1 0 256 0a256 256 0 1 0 0 512z\"\/><\/svg>\n      <\/span>\n      <span class='bde-icon-list__text' >\n      Integrierter \u00f6lfreier Kompressor f\u00fcr eine eigenst\u00e4ndige Gasversorgung\n      <\/span>\n              <\/div>\n      \n    <\/li>\n\n  \n              \n    <li>\n              <div class='bde-icon-list__item-wrapper'>\n      \n      <span class='bde-icon-list__icon' aria-hidden='true'>\n        <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 512 512\"><!--! Font Awesome Free 6.5.1 by @fontawesome - https:\/\/fontawesome.com License - https:\/\/fontawesome.com\/license\/free (Icons: CC BY 4.0, Fonts: SIL OFL 1.1, Code: MIT License) Copyright 2023 Fonticons, Inc. --><path d=\"M256 512A256 256 0 1 0 256 0a256 256 0 1 0 0 512z\"\/><\/svg>\n      <\/span>\n      <span class='bde-icon-list__text' >\n      Plug-and-Play-System ohne externe Druckluftquelle\n      <\/span>\n              <\/div>\n      \n    <\/li>\n\n  \n              \n    <li>\n              <div class='bde-icon-list__item-wrapper'>\n      \n      <span class='bde-icon-list__icon' aria-hidden='true'>\n        <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 512 512\"><!--! Font Awesome Free 6.5.1 by @fontawesome - https:\/\/fontawesome.com License - https:\/\/fontawesome.com\/license\/free (Icons: CC BY 4.0, Fonts: SIL OFL 1.1, Code: MIT License) Copyright 2023 Fonticons, Inc. --><path d=\"M256 512A256 256 0 1 0 256 0a256 256 0 1 0 0 512z\"\/><\/svg>\n      <\/span>\n      <span class='bde-icon-list__text' >\n      Stickstofferzeugung direkt vor Ort \u2013 ohne Druckgasflaschen\n      <\/span>\n              <\/div>\n      \n    <\/li>\n\n  \n              \n    <li>\n              <div class='bde-icon-list__item-wrapper'>\n      \n      <span class='bde-icon-list__icon' aria-hidden='true'>\n        <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 512 512\"><!--! Font Awesome Free 6.5.1 by @fontawesome - https:\/\/fontawesome.com License - https:\/\/fontawesome.com\/license\/free (Icons: CC BY 4.0, Fonts: SIL OFL 1.1, Code: MIT License) Copyright 2023 Fonticons, Inc. --><path d=\"M256 512A256 256 0 1 0 256 0a256 256 0 1 0 0 512z\"\/><\/svg>\n      <\/span>\n      <span class='bde-icon-list__text' >\n      Kompakte, zuverl\u00e4ssige und wartungsarme Bauweise\n      <\/span>\n              <\/div>\n      \n    <\/li>\n\n  \n              \n    <li>\n              <div class='bde-icon-list__item-wrapper'>\n      \n      <span class='bde-icon-list__icon' aria-hidden='true'>\n        <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 512 512\"><!--! Font Awesome Free 6.5.1 by @fontawesome - https:\/\/fontawesome.com License - https:\/\/fontawesome.com\/license\/free (Icons: CC BY 4.0, Fonts: SIL OFL 1.1, Code: MIT License) Copyright 2023 Fonticons, Inc. --><path d=\"M256 512A256 256 0 1 0 256 0a256 256 0 1 0 0 512z\"\/><\/svg>\n      <\/span>\n      <span class='bde-icon-list__text' >\n      Unterst\u00fctzt stabile und reproduzierbare Analysebedingungen\n      <\/span>\n              <\/div>\n      \n    <\/li>\n\n  <\/ul>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div><\/div>\n<\/section><section class=\"bde-section-2060-146 bde-section\">\n              \n  \n  \n\t\n\n\n\n<div class=\"section-container\"><div class=\"bde-div-2060-147 bde-div\">\n  \n  \n\t\n\n\n\n<h2 class=\"bde-heading-2060-148 bde-heading\">\nProduktauswahl\n<\/h2><div class=\"bde-code-block-2060-764 bde-code-block\">\n\n  <div class=\"spectbl-wrap\">\n  <table class=\"spectbl spectbl-grouped\">\n    <thead>\n      <tr>\n        <th rowspan=\"2\">Modell<\/th>\n        <th colspan=\"2\">Durchfluss<\/th>\n        <th colspan=\"2\">Reinheit*<\/th>\n        <th colspan=\"2\">Ausgangsdruck<\/th>\n        <th rowspan=\"2\">\n          Integrierter\n          <br>\n          Kompressor\n        <\/th>\n      <\/tr>\n      <tr>\n        <th class=\"spectbl-downrow\">Stickstoff<br>l\/min<\/th>\n        <th class=\"spectbl-downrow\">Trockenluft<br>l\/min<\/th>\n        <th class=\"spectbl-downrow\">Stickstoff<br>%<\/th>\n        <th class=\"spectbl-downrow\">Trockenluft<br>\u00b0C Taupunkt<\/th>\n        <th class=\"spectbl-downrow\">bar&nbsp;g<\/th>\n        <th class=\"spectbl-downrow\">psi&nbsp;g<\/th>\n      <\/tr>\n    <\/thead>\n\n    <tbody>\n      <tr>\n        <td>G6010<\/td>\n        <td>0,6<\/td>\n        <td>1,5<\/td>\n        <td class=\"spectbl-accent\">&gt; 99,999<\/td>\n        <td class=\"spectbl-accent\">\u221240<\/td>\n        <td>5<\/td>\n        <td>72,5<\/td>\n        <td>Ja<\/td>\n      <\/tr>\n\n      <tr>\n        <td>G7010<\/td>\n        <td>3<\/td>\n        <td>3<\/td>\n        <td class=\"spectbl-accent\">&gt; 99,999<\/td>\n        <td class=\"spectbl-accent\">\u221240<\/td>\n        <td>5<\/td>\n        <td>72,5<\/td>\n        <td>Ja<\/td>\n      <\/tr>\n    <\/tbody>\n  <\/table>\n\n  <div class=\"spectbl-notes\">\n    <p>* Stickstoffreinheit bezogen auf den Sauerstoffgehalt.<\/p>\n    <p>\n      Beide Modelle verf\u00fcgen \u00fcber einen integrierten \u00f6lfreien Kompressor und\n      ben\u00f6tigen keine externe Druckluftversorgung.\n    <\/p>\n    <p>\n      F\u00fcr die Ausf\u00fchrung mit 207\u2013253&nbsp;V bei 50\/60&nbsp;Hz wird der\n      Modellbezeichnung der Zusatz \u201e-E\u201c angeh\u00e4ngt, zum Beispiel G6010-E.\n      F\u00fcr die Ausf\u00fchrung mit 103\u2013126&nbsp;V bei 60&nbsp;Hz wird der Zusatz\n      \u201e-W\u201c verwendet, zum Beispiel G6010-W.\n    <\/p>\n  <\/div>\n<\/div>\n\n\n<\/div>\n<\/div><div class=\"bde-div-2060-227 bde-div\">\n  \n  \n\t\n\n\n\n<h2 class=\"bde-heading-2060-228 bde-heading\">\nTechnische Daten\n<\/h2><div class=\"bde-code-block-2060-769 bde-code-block\">\n\n  <div class=\"spectbl-wrap\">\n  <table class=\"spectbl spectbl-technical\">\n    <thead>\n      <tr>\n        <th colspan=\"2\">Technische Daten<\/th>\n      <\/tr>\n    <\/thead>\n\n    <tbody>\n      <tr>\n        <td>Umgebungstemperatur<\/td>\n        <td>5\u201345&nbsp;\u00b0C<\/td>\n      <\/tr>\n\n      <tr>\n        <td>Versorgungsspannung<\/td>\n        <td>\n          <strong>W-Modelle:<\/strong> 103\u2013126&nbsp;V, 60&nbsp;Hz\n          <br>\n          <strong>E-Modelle:<\/strong> 207\u2013253&nbsp;V, 50\/60&nbsp;Hz\n        <\/td>\n      <\/tr>\n\n      <tr>\n        <td>Anschl\u00fcsse<\/td>\n        <td>\n          <div class=\"spectbl-connections\">\n            <div>\n              <strong>Stickstoffausgang G6010:<\/strong>\n              \u215b\u2033-Klemmringverschraubung\n            <\/div>\n\n            <div>\n              <strong>Stickstoffausgang G7010:<\/strong>\n              \u00bc\u2033-Klemmringverschraubung\n            <\/div>\n\n            <div>\n              <strong>Trockenluftausgang:<\/strong>\n              entsprechend der jeweiligen Ger\u00e4teausf\u00fchrung\n            <\/div>\n          <\/div>\n        <\/td>\n      <\/tr>\n    <\/tbody>\n  <\/table>\n\n  <div class=\"spectbl-notes\">\n    <p>\n      Beide Modelle verf\u00fcgen \u00fcber einen integrierten \u00f6lfreien Kompressor und\n      ben\u00f6tigen keine externe Druckluftversorgung.\n    <\/p>\n    <p>\n      F\u00fcr die Ausf\u00fchrung mit 207\u2013253&nbsp;V wird der Modellbezeichnung der\n      Zusatz \u201e-E\u201c angeh\u00e4ngt. F\u00fcr die Ausf\u00fchrung mit 103\u2013126&nbsp;V wird der\n      Zusatz \u201e-W\u201c verwendet.\n    <\/p>\n  <\/div>\n<\/div>\n\n\n<\/div>\n<\/div><div class=\"bde-div-2060-258 bde-div\">\n  \n  \n\t\n\n\n\n<h2 class=\"bde-heading-2060-259 bde-heading\">\nGewichte und Abmessungen\n<\/h2><div class=\"bde-code-block-2060-765 bde-code-block\">\n\n  <div class=\"spectbl-wrap\">\n  <table class=\"spectbl spectbl-grouped\">\n    <thead>\n      <tr>\n        <th rowspan=\"2\">Modell<\/th>\n        <th colspan=\"2\">H\u00f6he (H)<\/th>\n        <th colspan=\"2\">Breite (B)<\/th>\n        <th colspan=\"2\">Tiefe (T)<\/th>\n        <th colspan=\"2\">Gewicht<\/th>\n      <\/tr>\n      <tr>\n        <th class=\"spectbl-downrow\">mm<\/th>\n        <th class=\"spectbl-downrow\">Zoll<\/th>\n        <th class=\"spectbl-downrow\">mm<\/th>\n        <th class=\"spectbl-downrow\">Zoll<\/th>\n        <th class=\"spectbl-downrow\">mm<\/th>\n        <th class=\"spectbl-downrow\">Zoll<\/th>\n        <th class=\"spectbl-downrow\">kg<\/th>\n        <th class=\"spectbl-downrow\">lbs<\/th>\n      <\/tr>\n    <\/thead>\n\n    <tbody>\n      <tr>\n        <td>G6010<\/td>\n        <td>842<\/td>\n        <td>33,1<\/td>\n        <td>345<\/td>\n        <td>13,6<\/td>\n        <td>413<\/td>\n        <td>16,3<\/td>\n        <td>58<\/td>\n        <td>127,9<\/td>\n      <\/tr>\n\n      <tr>\n        <td>G7010<\/td>\n        <td>874<\/td>\n        <td>34,4<\/td>\n        <td>345<\/td>\n        <td>13,6<\/td>\n        <td>663<\/td>\n        <td>26,1<\/td>\n        <td>93<\/td>\n        <td>205<\/td>\n      <\/tr>\n    <\/tbody>\n  <\/table>\n\n  <div class=\"spectbl-notes\">\n    <p>\n      Beide Modelle verf\u00fcgen \u00fcber einen integrierten \u00f6lfreien Kompressor.\n    <\/p>\n  <\/div>\n<\/div>\n\n\n<\/div>\n<\/div><div class=\"bde-div-2060-394 bde-div\">\n  \n  \n\t\n\n\n\n<h2 class=\"bde-heading-2060-395 bde-heading\">\nVorbeugende Wartung\n<\/h2><div class=\"bde-code-block-2060-767 bde-code-block\">\n\n  <div class=\"spectbl-wrap\">\n  <table class=\"spectbl\">\n    <thead>\n      <tr>\n        <th>Wartungssatz<\/th>\n        <th>Artikelnummer<\/th>\n        <th>Geeignet f\u00fcr<\/th>\n        <th>Wechselintervall<\/th>\n      <\/tr>\n    <\/thead>\n\n    <tbody>\n      <tr>\n        <td>Filtersatz \u2013 G6 mit Kompressor<\/td>\n        <td>606272351<\/td>\n        <td>G6010<\/td>\n        <td class=\"spectbl-accent\">12 Monate<\/td>\n      <\/tr>\n\n      <tr>\n        <td>Kompressorsatz, 230 V \u2013 G6<\/td>\n        <td>606272336<\/td>\n        <td>G6010 in 230-V-Ausf\u00fchrung<\/td>\n        <td class=\"spectbl-accent\">12 Monate<\/td>\n      <\/tr>\n\n      <tr>\n        <td>Kompressorsatz, 120 V \u2013 G6<\/td>\n        <td>606272337<\/td>\n        <td>G6010 in 120-V-Ausf\u00fchrung<\/td>\n        <td class=\"spectbl-accent\">12 Monate<\/td>\n      <\/tr>\n\n      <tr>\n        <td>Filtersatz \u2013 G7 mit Kompressor<\/td>\n        <td>606272352<\/td>\n        <td>G7010<\/td>\n        <td class=\"spectbl-accent\">12 Monate<\/td>\n      <\/tr>\n\n      <tr>\n        <td>Kompressorsatz, 230 V \u2013 G7<\/td>\n        <td>606272334<\/td>\n        <td>G7010 in 230-V-Ausf\u00fchrung<\/td>\n        <td class=\"spectbl-accent\">12 Monate<\/td>\n      <\/tr>\n\n      <tr>\n        <td>Kompressorsatz, 120 V \u2013 G7<\/td>\n        <td>606272335<\/td>\n        <td>G7010 in 120-V-Ausf\u00fchrung<\/td>\n        <td class=\"spectbl-accent\">12 Monate<\/td>\n      <\/tr>\n    <\/tbody>\n  <\/table>\n\n  <div class=\"spectbl-notes\">\n    <p>\n      F\u00fcr beide Modelle sind separate Filter- und Kompressors\u00e4tze vorgesehen.\n      Beim Kompressorsatz ist die jeweilige Versorgungsspannung des Generators\n      zu beachten.\n    <\/p>\n  <\/div>\n<\/div>\n\n\n<\/div>\n<\/div><\/div>\n<\/section>","protected":false},"excerpt":{"rendered":"<p>Hochreiner Stickstoff und Trockenluft f\u00fcr Analyseger\u00e4te G6\/G7 \u2013 Stickstoff- und Trockenluftgeneratoren Die Parker G6\/G7-Generatoren erzeugen hochreinen Stickstoff und trockene Druckluft f\u00fcr analytische Anwendungen. Sie eignen sich insbesondere f\u00fcr Analyseger\u00e4te, die eine kontinuierliche und zuverl\u00e4ssige Versorgung mit beiden Gasen ben\u00f6tigen. Je nach Modell stehen unterschiedliche Durchflussleistungen f\u00fcr Stickstoff und Trockenluft zur Verf\u00fcgung.Der G6010 liefert bis zu [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"parent":2030,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_breakdance_hide_in_design_set":false,"_breakdance_tags":"","footnotes":""},"class_list":["post-2060","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/wicom.com\/gasgenerator\/wp-json\/wp\/v2\/pages\/2060","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wicom.com\/gasgenerator\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/wicom.com\/gasgenerator\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/wicom.com\/gasgenerator\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/wicom.com\/gasgenerator\/wp-json\/wp\/v2\/comments?post=2060"}],"version-history":[{"count":5,"href":"https:\/\/wicom.com\/gasgenerator\/wp-json\/wp\/v2\/pages\/2060\/revisions"}],"predecessor-version":[{"id":2131,"href":"https:\/\/wicom.com\/gasgenerator\/wp-json\/wp\/v2\/pages\/2060\/revisions\/2131"}],"up":[{"embeddable":true,"href":"https:\/\/wicom.com\/gasgenerator\/wp-json\/wp\/v2\/pages\/2030"}],"wp:attachment":[{"href":"https:\/\/wicom.com\/gasgenerator\/wp-json\/wp\/v2\/media?parent=2060"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}